(60598标准中谈到光生物安全,引入了IEC/TR62778(测试指导文件,并非标准,注重点在蓝光危害部分),并且将软管灯单独列出标准60598-2-21)
0.1
This Part 1 of IEC 60598 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1000 V. The requirements and related tests of this standard cover: classification, marking, mechanical construction, electrical construction and photobiological safety
0.2
IEC/TR 62778, Application of IEC 62471 for the assessment of blue light hazard to light.
0.4.2
Except where otherwise specified in the sections of Part 1 or Part 2, luminaires shall be tested as delivered, and installed as for normal use, in
an ambient temperature of between 10 °C and 30 °C, having regard to the manufacturer's installation instructions. The lamp (or lamps) is (are) not included except where essential for the test.
(测试环境10-30度,正常安装)
0.6
新增 Part 2-21 Sealed lighting chains.
新增 NOTE In this edition of IEC 60598-1 all requirements listed in IEC 60598-2-6 have been incorporated. As a consequence, IEC 60598-2-6 will be withdrawn after publication of this standard. For this reason, compliance to IEC 60598-2-6 for luminaire with built-in transformer or controlgear, is not required when tested according to this edition of IEC 60598-1.